空压机不能启动:
空压机不能启动:
The air compressor cannot be started:
1.没有主电源或控制电压
1. There is no main power supply or control voltage
2.检查供电检查控制电路保险丝
2. Check the fuse of power supply control circuit
3.检查变压器次级线圈的控制电压
3. Check the control voltage of the secondary coil of the transformer
4.星形/三角形接法计时器损坏 更换星形/三角形接法计时器
4. The star / triangle connection timer is damaged. Replace the star / triangle connection timer
二、定期停机:
2、 Periodic shutdown:
1.主机排气温度高 加满冷却剂
1. The exhaust temperature of the main engine is high. Fill up the coolant
2.电机超载 将过载设置为正确值并切换为手动复位
2. Motor overload set the overload to the correct value and switch to manual reset
3.线压波动超出范围 确保启动时电压下降不超过10%,运转时电压不超过6%
3. The fluctuation of line voltage exceeds the range, and ensure that the voltage drop during startup does not exceed 10% and the voltage during operation does not exceed 6%